15
NOTE:
Keep at least a distance of 1 U (44.45 mm, or 1.75 in) between devices for proper heat dissipation.
Grounding the device
ARNING!
• Correctly connecting the device grounding cable is crucial to lightning protection and EMI protection.
• Connect the
roundin
cable to the
roundin
system in the equipment room. Do not connect it to a fire
main or lightning rod.
To ground the device:
1. Use a Phillips screwdriver to remove the grounding screw from the chassis.
2. Use the grounding screw to attach one end (with ring terminal) of the grounding cable to the
chassis.
3. Connect the other end of the grounding cable according to the grounding method you use:
{ Ground the device with a grounding strip—If a grounding strip is available at the installation
site, connect the other end of the grounding cable to the grounding strip and make sure the
grounding strip has been correctly grounded.
Figure 16 Grounding the device with a grounding strip
{
Ground the device with the rack—Connect the other end of the grounding cable to the
grounding point on the rack and make sure the rack has been correctly grounded.
Komentáře k této Příručce