H3c-technologies H3C MSR 20-1X Uživatelský manuál Strana 70

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 75
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 69
63
Setting the Fixed E1 Interface Impedance
CAUTION:
Positions of DIP switches should be performed by H3C personnel or an Authorized H3C partner.
By default, the impedance of the fixed E1 interface on MSR 20-12 is 75-ohm. Using the internal DIP
switches, users can change the interface impedance from 75-ohm to 120-ohm.
Figure 46 Default setting of DIP switches
on
1
2
3
4
5
6
7
8
Description of DIP switch settings is given in the following table:
Table 2 Description of DIP switch settings
DIP Description
Configuration of
75-ohm impedance
Configuration of
120-ohm impedance
1BIT ON OFF
2BIT ON OFF
3BIT ON OFF
4BIT ON OFF
5BIT
75-ohm/120-ohm
selection switch
ON OFF
6BIT
RxRing grounding mode
selection switch
OFF: RxRing is grounded
via capacitance.
ON: RxRing is grounded
directly.
7BIT
RxShield grounding
mode selection switch
ON: RxShield is
grounded.
OFF: RxShield is not
grounded.
8BIT
SxShield grounding
mode selection switch
OFF: RxShield is
grounded via
capacitance
ON: RxShield is
grounded directly.
Zobrazit stránku 69
1 2 ... 65 66 67 68 69 70 71 72 73 74 75

Komentáře k této Příručce

Žádné komentáře