Installation Manual
H3C SecPath F100-C-EI Firewall
Chapter 3 Installing the Firewall
3-7
z The neutral point of the socket must be grounded reliably.
Normally, the neutral point of the power source in a building
was buried in the earth during construction and cabling.
z Make sure that the power source in the building is properly
grounded before connecting the AC power cord.
III. Connect the AC power cord
1) Make sure the PGND is properly connected to earth ground.
2) Connect one end of the AC power cord shipped with the
device to the AC input socket on the chassis and the other
end to the AC mains supply.
Figure 3-7 Connecting the AC power cord
3) Check the status of the PWR LED on the front panel. For
LED status description, refer to
Table 1-2 on page 1-5.