the system and application software on the OAP board. After the switch, you can press Ctrl+K to return
to the command line interface on the device.
Follow the step to redirect from the device to the OAP board:
To do… Use the command… Remarks
Redirect from the device to the
OAP board
oap connect slot
0
Required
Available in user view
Resetting the System of an OAP Board
If the operating system of an OAP board works abnormally or is under other anomalies, you can reset
the OAP board with the following command.
The OAP board has its independent CPU; therefore, the access controller can still recognize and
control the OAP board after you reset the OAP system.
Follow the step to reset the system of the OAP board:
To do… Use the command… Remarks
Reset the system of the OAP board
oap reboot slot
0
Required
Available in user view
Reset of the OAP board may cause data loss and service interruption. Therefore, before resetting the
OAP board, you need to save the data on the operating system to avoid service interruption and
hardware data loss.