<Sysname> display fan
Fan 1 State: Normal
Fan 2 State: Normal
Fan 3 State: Normal
Fan 4 State: Normal
Table 14 Output description
Field Descri
p
tion
Fan Number of the fan.
State
Fan state:
Normal—The fan is operating properly.
Absent—The fan is not in position.
Abnormal—The fan has failed.
Displaying the operational status of power modules
Use the display power command to display the operational status of power modules.
<Sysname> display power
Power Information:
Power 1 Status: Normal
Power 2 Status: AbNormal
Table 15 Output description
Field Descri
p
tion
Power Number of the power module.
Status
Power module state:
Normal—The power module is operating properly.
Absent—The power module is not in position.
Abnormal—The power module has failed.
Displaying the temperature information of the
firewall
Use the display environment command to display the temperature information of the firewall.
<Sysname> display environment
System Temperature information (degree centigrade):
--------------------------------------------------------------------------------
---------
Sensor Temperature LowerLimit Warning-UpperLimit Alarm-UpperLimit Shutdown-U
pperLimit
hotspot 1 27 0 60 70 NA
hotspot 2 46 0 80 92 NA
hotspot 3 32 0 60 70 NA